TECNICAL SPECIFICATION
1. STANDART CONTAINERS
2. DE-MOUNTABLE CONTAINERS
STANDART CONTAINERS
PRODUCTION TYPE

Modular Construction with GALVANIZED trapezoidal sectioned demountable metal sheet body is de-mountable.
Type-1 Containers are manufactured with the sizes of 2.40X6.00X2.60 m and
Type-2 Containers are manufactured with the sizes of size of 3.00x7.00x2.60 m.
Apprx.weight of containers for
Type-1 is 2.40X6.00:1500 kg, and
Type-2 is 3.00x7.00:2500 kg. All materials certificated by TSE.
TECHNICAL DATAS
Snow Load : 80 kg/m²
Wind Speed : 100 km/h
External Wall Heat Transmission Coefficient : K: 0.74 Kcal/m²hC
Internal Wall Heat Transmission Coefficient : K: 0.69 Kcal/m²hC
Roof Heat Transmission Coefficient : K: 0.68 Kcal/m²hC
Floor Heat Transmission Coefficient : 200 kg/m²( Calculated in accordance with T.S 498 )
Base-Plate(chassis) Load Capacity : 200 kg/m²( Calculated in accordance with T.S 498 )
EXTERNAL WALLS:
External Wall Height : 2600 mm
Internal Clear Height : 2320 mm.
Outer Surface Covering : 35 mm roll depth, 0.80 mm thick, GALVANIZED trapezoidal sectioned steel sheets.
Insulation : 40 mm expanded polystyrene foam (10/12 kg/m³)
INTERNAL WALLS:
Internal Wall Height : 2320 mm
Surface Covering : PVC Panelling. (If required 8mm thick,white colored, Fireproof, FIBERCEMENT board- B1 DIN 4102 Part 1)
Insulation : 40 mm thick expanded polystyrene foam.(10/12 kg/m³)
FLOOR COVERING:
Construction : Construction comprised of horizontal profiles
Covering : Vinyl Tile (300x300x1.6mm foil covered) as floor covering on the 16mm thick,Fireproof,FIBER CEMENT board B1 DIN 4102 Part 1 class and in wet volumes PVC (mineflo).
CEILING COVERING:
Covering : PVC Panelling. (If required 8mm thick,white colored, Fireproof, FIBERCEMENT board
ROOF:
Roof Construction : Special shaped outer frame, bearing box profiles (Rain water will be discharged by 4 corners columns of the container)
Covering : 27 mmx200 mm roll depth, 0.55 mm thick galvanized trapezoidal sectioned unpainted steel sheets
Insulation : 80 mm mattress glass wool (14 kg/m3)
DOOR JOINERIES:
External Doors (2 mm thick DKP steel sheet framed: 800/1950 mm insulated steel sheet door (outer size).Expanded polystrene (0,50 mm thick) foam insulation in between galvanized steel sheets, Leaf thickness :45 mm. Special formed door frames with rubber gasket.
Internal Doors (2 mm DKP steel sheet framed) : 800/1950 mm Mdf-slide Press door (outer size), Leaf thickness :42 mm
Wet Volume Doors (2 mm thick DKP steel sheet framed ) : 700x1950 mm mdf-slide (outer size), Leaf thickness :42 mm
Door Lock and Handle : External doors have cylindirical ,internal doors have encased locks with grey coloured metal door handles.
WINDOW JOINERIES (EGEPEN DECEUNINCK) :
Window (2 mm thick DKP steel sheet framed) : 1000/1200 mm PVC with PVC handles
Kitchen-wc-shower area : Dia 120 mm electrical, kitchen-type extractor fan with lid.
GLASS:
Single Glazing : 4 mm
Double Glazing : 4+9+4 mm (OPTIONAL)
PAINT:
Outer Facade, external door and window frames : Galvanized steel sheets with RAL 9002 (Broken White Colored) furnace painted.
Internal Door Frames : 1 layer rapid primer + 1 layer semi- synthetic oily based paint – Broken White Colored.
Outer Corners : 1 layer rapid primer + 1 layer semi- synthetic oily based paint – will be applied with special membraned dust painting tools.
BELT COLORS : RAL 5022 DARK BLUE . Other metal parts (base plate(chassis),bearing construction ): 1 layer rapid Primer
ELECTRICAL and PHONE INSTALLATION (Under the plaster):
(The installation will be done over the plaster in case of using FIBER CEMENT boards or chipboard as internal coverings )
Cabling : 2000W,220 V),Socket Cables:3X2.5 mm² NYM,Lighting Cables:2x1.5 mm² NYM
Lighting Armatures :
Usual Areas Round Type Armatures
Wet volume,Over exit door Globe –IP 44
Electrical Sockets,switch : Appropriate number will be supplied in accordance with the plan
Fuses and fuses boxes : Appropriate number will be supplied in accordance with the plan
Phone sockets : Appropriate number will be supplied in accordance with the plan
SANITARY INSTALLATION(Under the plaster):
Vitreous / Armatures:
Lavatory/Washbasin : 37x45 cm Wall type
Lavatory and shower taps : Taps are wall mounted in cold water installation lavatories and taps have outlets from lavatories in hot water installation lavatories
Water Closet : Western style water closet with WC taps .Plastic flushing cistern
Shower Tray : 70 cmx70 cm Polyester
Kitchen Sink : Chromium-plated 50/100 cm double, lower chipboard cupboard.No cupboard above the sink.
Accessories : PVC mirror, closet lid
Pipes:
Clean water : PPRC
Waste water : PVC
LIFTING SYSTEM:
The loading and unloading facility shall be made by connecting the steel ropes lying in the same interval to the iron Lifting eyes mounted hiddenly on the corners, to the lockers.If required the containers shall be two or multi-storied. The transport system of all containers will be organized by concerning that specification.
DE-MOUNTABLE CONTAINERS
PRODUCTION TYPE
Standart Containers are manufactured with the sizes of 2.35x6.00x2.60 m
But we can change the dimensions up to your demands,
All materials certificated by TSE.
TECHNICAL DATAS
External Wall Heat Conduction Coefficient :K: 0.47 Kcal/m²hC
Internal Wall Heat Conduction Coefficient :K: 0.45 Kcal/m²hC
Roof Heat Conduction Coefficient :K: 0.68 Kcal/m²hC
Floor Heat Conduction Coefficient :K: 3.85 Kcal/m²hC
Base-Plate(chassis) Load Capacity :200 kg/m²
Snow Load : 80 kg/m²
Wind Velocity :102 km/saat
EXTERNAL WALLS
External Wall Height:2600 mm
Internal Net Wall Height:2320 mm
External Wall Panel :40 mm thick polyurethane foam (40 kg/m3) insulation injected in between 0.50 mm outer surface and 0,40 mm thick inner surface with galvanized steel sheet.
RAL 9002 painted galvanized polyurethane sandwich wall panel.
INTERNAL WALLS
Internal Net Wall Height :2320 mm
Internal Wall Panel :40 mm thick polyurethane foam (40 kg/m3) insulation injected in between 0.50 mm outer surface and 0,40 mm thick inner surface with galvanized steel sheet.
RAL 9002 painted galvanized polyurethane sandwich wall panel
FLOOR COVERING
Construction :Construction comprised of horizontal profiles
Covering :Vinyl Tile (300x300x1.6mm foil covered) as floor covering on the 16mm thick,Fireproof BETOPAN boards (B1 DIN 4102 Part 1) class
Insulation (OPTIONAL):0.50 mm thick natural galvanized trapezoidal sectioned metal sheet over the construction with horizantal profiles+20 mm thick expanded polystrene foam(10-12 kg/m3) +16 mm thick, Fireproof BETOPAN boards (B1 DIN 4102 Part 1) class + vinyl tile (300x300x1.6mm foil covered)
.Floor Heat Conduction Coefficient: K:1.19 Kcal/m2hC
CEILING COVERING
Covering :PVC Panelling.
ROOF
Roof Construction :U shaped outer frame, bearing box profiles
(Rain water will be discharged by 4 corners columns of the container)
Covering :27 mmx200 mm roll depth, 0.50 mm thick galvanized trapezoidal sectioned unpainted steel sheets
Insulation :80 mm mattress glass wool (14 kg/m3)
DOOR JOINERIES
External Doors (1,2 mm thick galvanized steel sheet framed) :935/1960 mm insulated steel sheet door (outer size).Expanded polystrene foam insulation in between 0,50 mm thick ,RAL 9002 painted,galvanized steel sheets.Including special formed door frames with rubber gasket.
Internal Doors (1,2 mm galvanized steel sheet framed) :840/1960 mm Mdf-slide Press door (outer size),
Wet Volume Doors (1,2 mm thick galvanized steel sheet framed ):620x1960 mm mdf-slide (outer size),
Door Lock and Handle :External doors have cylindirical ,internal doors have encased locks with grey coloured metal door hadles.
WINDOW JOINERIES
Window (1.2 mm thick galvanized steel sheet framed) :945/1205 mm PVC with PVC handles
GLASS
Single Glazing :4 mm
Double Glazing :4+9+4 mm (OPTIONAL)
PAINT
All metal surfaces are painted with double coating, double layer synthetic. (External door and window frames , Outer Corners, base plate(chassis), bearing construction)
ELECTRICAL AND PHONE INSTALLATION (Over the plaster)
The cables are HES brand, for the fuses Siemens automates are used. For the sockets cables of 2 X 2.5, lighting 2 X 1.5 are used. The keys and sockets are VIKO brand. In each room, there is one key, one socket and one telephone socket.
OPTINAL: Split air conditioning installation will be made at the container.
SANITARY INSTALLATION:
İnstallations will be given but not be installed. İnstallation is customers responsibility.
Vitreous / Armatures :
Lavatory/Washbasin :37x45 cm Wall type
Lavatory and shower taps :Taps are wall mounted in cold water installation lavatories and taps have outlets from lavatories in hot water installation lavatories.
Water Closet :Western style water closet with WC taps .Plastics flushing cistern .
Shower Tray :70 cmx70 cm Mermerit
Kitchen Sink :Chromium-plated 50/100 cm double, lower chipboard cupboard.No cupboard above the sink.
Accessories :PVC based mirror,shelf and closet lid.
Pipes :
Clean water:PPRC
Waste water :PVC
LIFTING SYSTEM
The loading work is being made by connection of the steel cables with equal distance to the hidden eye bolts on corners to the locks.
The transport system of all containers will be organized by concerning that specification.
|
 |